Step | | Procedure & Parts & Tools |
1 |
|
PUSH IN ON THE 2 ORANGE TABS TO REMOVE THE BASE COVER.
|
2 |
|
REMOVE THE BASE COVER.
|
3 |
|
LOOSEN THE BRUSH HEIGHT KNOB AND REMOVE IT. SET IT ASIDE.
|
4 |
|
FLIP THE BASE OVER AND REMOVE THE 5 SCREWS.
Screwdriver-phillips |
|
|
5 |
|
FLIP THE BASE BACK OVER AND REMOVE THE BRUSH MOTOR COVER.
|
6 |
|
LOCATE THE RED MICROSWITCH. DISCONNECT THE BROWN AND BLACK WIRES FROM THE CONTROL BOARD. SET VOLT METER TO VOLTAGE. INSERT VOLT METER LEADS INTO THE WIRE CONNECTORS. PLUG THE MACHINE IN. ACTIVATE THE MACHINE. THE VOLT METER SHOULD READ APPROX. 120 VOLTS. IF MICROSWITCH IS OKAY, REVERSE STEPS 1 THRU 5 TO REASSEMBLE THE MACHINE.
Volt meter (True RMS capable) |
|
|